Densitometers

High Performance and Reliability
Ihara Electronic Industries utilizes advanced microcomputer technology to ensure superior performance and reliability for its entire line of densitometric products. Standard functions include:

  • density
  • density difference
  • dot area
  • dot gain
  • trap
  • print contrast
  • hue error
  • grayness
  • saturation
  • cast
  • brightness
  • auto-function
  • dot analysis

Menu Driven Commands
Simply select the functions desired. No memorization or operation manual required.

Self-guiding Prompts
Clear and concise instructions are prompted across the large graphic LCD display in every measurement

Help Key Provides Explanation of Key Functions
Detailed explanations are available for all measurement functions along with answers to frequently asked questions

Quick Calibration
It takes seconds to calibrate using the quick calibration function. Standard Calibration is also available.

Auto-Function
Auto-function allows the user to measure density, dot gain and ink trap, interchangeably.

Large Graphic LCD Display
The easy to read graphic LCD display allows the user to determine the precise configuration desired, including right or left handed view, two or three decimal precision and display options.

Printer and Computer Interface
The configurable RS-232C serial interface is capable of linking the densitometer to a computer or to the Ihara PR-95 printer.

Security User Code (optional)
As an option to safeguard your investment, the densitometer may be set to operate only with the correct user code.


R720 
Color Reflection De
nsitometer                               Part Number EQP-IHR720    
Color Reflection Densitometer w/plate Function  Part Number EQP-IHR720P  



Ask about our 14 day trial!

Measurement Functions Recharge Time
Density Approximately 1.5 Hours
Dot Area (Murray-Davies or Yule-Nielsen) Measurements Per Charge
Dot Gain Approximately 4,000 (internal testing)
Density Difference

Warm Up Time

Auto-Function (Automatically measures density or None
dot gain) Measuring Time
Filter Response Approximately 1 second
Status T Operating Temperature Range
Status E 41ºF ~ 104ºF (5ºC ~ 40ºC)
Status A Polarization Filter
Measuring Geometry (optional)
0º/45º (ANSI PH2.17, ISO 5/4, DIN 16536) Security User Code
Measuring Range (optional)
Density 0.00D-2.50D Dimensions
Dot Area 0%-100% 2 3/4"W x 2"H x 8 1/4"L
Repeatability (72mm x 50mm x 210mm)
± 1.01D or 1% Weight
Accuracy 1.2 lbs (with batteries)
± 0.02D or 2% (530g)
Light Source Computer Output
Halogen Lamp, Approximately 2856ºK Configurable RS-232C Serial Interface
Aperture Diameter Accessories
3.0mm (1.7mm optional) Operation Manual
Detector Calibration Standard
GaAsP Photodiode AC Adapter (9V, 500mA, center-negative)
Display Carrying Case
128 x 64 Dot Graphic LCD Serial Interface Cable (optional)

Power Supply

Ihara PR-95 Printer (optional)
Ni-Cad (4.8V), 800mAh Software (optional)
  Cable Harness (optional)
 
Revised February 27, 2010

      GWJ co
          
Hacienda Heights, CA 91745

         Phone 626-336-1134  800-336-1138(USA)
       Fax 626-336-2409

       Copyright © 1997-2010 GWJ Co. All rights reserved.
Other products and companies referred to herein are trademarks